ham:equipment:power:supply
Table of Contents
12V DC Power Distribution & Battery Log
Last Updated: YYYY-MM-DD Standard Connector: Anderson Powerpole (30A / 45A, ARES/RACES Color Standard: Red Left, Black Right, Tongue Down)
Primary Shack Power Sources
| Source | Make / Model | Output Rating | Backup / Failover Role | Notes |
|---|
| Main AC-DC PSU | e.g., Astron RS-35M / Samlex SEC-1235M | 13.8V DC @ 30A Cont. | Primary Base Supply | Linear / Switching; low RF noise floor verified |
| Backup Battery | e.g., Bioenno BLF-1220A (LiFePO4) | 12.8V Nominal, 20Ah | Automatic Failover via PWRgate | Built-in BMS; max continuous discharge 40A |
| Auto-Switch / Charger | e.g., West Mountain Radio Epic PWRgate | 40A Max Load | Seamless AC-to-Battery Switch | Float/Charge set to 14.4V LiFePO4 profile |
| Solar Charge Controller | e.g., Genasun GV-10-Li-14.2V | 10A MPPT | Field / Extended Outage | RF-quiet MPPT; paired with 100W folding panel |
Powerpole Distribution Strip Map
Documenting every port on your RigRunner or fused distribution block prevents blown fuses and simplifies troubleshooting.
| Port # | Connected Device | Wire Gauge | Fuse Rating | Idle Draw | Max TX Draw | Notes |
|---|
| Input | Epic PWRgate Output | #10 AWG | 40A | — | — | Main feed from PSU / Battery |
| Port 1 | HF Transceiver (100W) | #10 AWG | 25A | 1.2A | 21.0A | Factory cable terminated with 45A Powerpoles |
| Port 2 | VHF/UHF Dual-Band Rig | #12 AWG | 15A | 0.5A | 11.5A | 50W High Power setting |
| Port 3 | Automatic Antenna Tuner | #16 AWG | 5A | 0.1A | 0.8A | Powered only during tuning cycle |
| Port 4 | TNC / Digital Interface | #18 AWG | 3A | 0.2A | 0.2A | Always-on APRS / Winlink gateway |
| Port 5 | Shack LED Desk / Meter Lights | #18 AWG | 3A | 0.3A | 0.3A | — |
| Port 6 | Spare / Auxiliary | — | — | — | — | Reserved for portable test bench |
Battery Inventory & Capacity Test Log
Track resting voltage, load tests, and charge cycles for shack backup and portable POTA/SOTA batteries.
| Battery ID | Chemistry & Rating | Purchase Date | BMS Cutoff (LVC) | Last Capacity Test | Measured Ah | Health Status |
|---|
| BAT-01 (Shack) | LiFePO4 12V 20Ah | YYYY-MM-DD | 10.0V | YYYY-MM-DD | 19.8 Ah (99%) | Excellent |
| BAT-02 (POTA) | LiFePO4 12V 6Ah | YYYY-MM-DD | 10.0V | YYYY-MM-DD | 5.9 Ah (98%) | Excellent |
| BAT-03 (HT / QRP) | LiFePO4 12V 3Ah | YYYY-MM-DD | 10.0V | YYYY-MM-DD | 2.8 Ah (93%) | Good |
Power Outage & Runtime Calculation
- Typical Shack Idle Load: ~2.0A (HF RX + VHF RX + TNC)
- Typical TX Duty Cycle (FT8 / SSB): ~6.5A average hourly draw (at 50W–100W)
- Estimated Runtime on 20Ah LiFePO4:
- *Receive / Monitoring Only:* ~9–10 hours
- *Active Emergency Net / FT8:* ~3 hours (without solar replenishment)
Maintenance & Safety Notes
- Low-Voltage Alarm: RigRunner audible alarm set to trigger at 11.5V under load.
- Storage Voltage: Portable LiFePO4 batteries stored at ~50–60% state of charge (13.1V–13.2V resting) when inactive for >30 days.
- Spare Fuses: Taped inside the lid of the shack power supply (3A, 5A, 15A, 25A, 40A ATC automotive blade fuses).
ham/equipment/power/supply.txt · Last modified: by N5JLD