Table of Contents

Standard Operating Procedures: Pre-Flight Inspection & Maintenance

AIRWORTHINESS MANDATE (14 CFR § 107.15): No person may operate a civil small unmanned aircraft system unless it is in a condition for safe operation. Prior to each flight, the Remote Pilot in Command (RPIC) must inspect the UAS to ensure it is safe to fly.

1. Pre-Deployment Preparation (24 Hours Prior)

Before traveling to the operational site, the RPIC or Equipment Technician must verify hardware readiness and firmware stability.

2. On-Site Pre-Flight Inspection Checklist

This physical and system inspection must be executed sequentially before every flight or battery swap.

2.1 Airframe & Mechanical Inspection

  1. [ ] Fuselage & Frame Arms: Inspect for hairline cracks, stress whitening, loose screws, or warping—especially around motor mounts and folding arm hinges.
  2. [ ] Landing Gear: Confirm struts are firmly attached, undamaged, and free of debris.
  3. [ ] Propellers (Critical):
    • Inspect every blade for nicks, chips, cracks, delamination, or bending. Replace damaged blades immediately—never fly with a chipped propeller.
    • Verify propellers are mounted on the correct motors (CW vs. CCW) and locking mechanisms snap securely into place.
  4. [ ] Motors: Spin each motor manually by hand. Verify smooth rotation with no grinding, clicking, magnetic rubbing, or excessive vertical shaft play.
  5. [ ] Payload & Gimbal:
    • Remove gimbal clamp/cover before powering on the aircraft.
    • Check rubber vibration dampers for tears or dry rot.
    • Clean camera lens and optical/obstacle-avoidance sensors with a microfiber cloth.

2.2 Battery & Power System Inspection

  1. [ ] Physical Condition: Inspect battery casing for swelling (“puffing”), punctures, dents, cracks, or chemical odor. Quarantine any swollen battery immediately.
  2. [ ] Terminals: Verify gold power pins on both the battery and aircraft battery bay are clean, straight, and free of carbon arcing or moisture.
  3. [ ] Battery Latch: Insert the battery firmly and physically tug on it to confirm the locking latches are fully engaged.

2.3 Avionics, GCS & Telemetry Check

  1. [ ] Controller & Antennas: Power on the GCS first, then the aircraft. Unfold antennas and orient them parallel to each other (flat faces pointed toward the aircraft's flight area).
  2. [ ] Satellite Lock (GNSS): Verify strong GPS/GLONASS/Galileo lock (minimum 10–12 satellites recommended before takeoff).
  3. [ ] Compass & IMU Status: Check the flight app sensor menu for normal green status. Calibrate the compass only if prompted or when operating more than 50 miles from the previous flight site—away from rebar, vehicles, and buried power lines.
  4. [ ] Failsafe Verification: Confirm Return-to-Home (RTH) altitude is set at least 50 ft (15 m) above the tallest obstacle in the area, and verify Lost-Link behavior is set to RTH (or Hover/Land as required by indoor/canopy ops).
  5. [ ] Remote ID: Confirm the Remote ID broadcast status shows active and error-free on the GCS display.

2.4 Takeoff & Hover Test

  1. [ ] Clear Takeoff Zone: Ensure all personnel and bystanders are at least 30 feet (10 meters) away from the launch pad.
  2. [ ] Controlled Ascent: Launch to 10–15 feet (3–5 meters) AGL and hold a stationary hover for 15–20 seconds.
  3. [ ] Control & Audio Check:
    • Listen for abnormal high-pitched motor whining or unbalanced propeller vibration.
    • Test pitch, roll, yaw, and throttle inputs gently to confirm crisp response.
    • Verify battery voltage remains stable under load without sudden cell-drop warnings.

3. Post-Flight & Turnaround Procedures

  1. Power-Down Sequence: Land completely, disarm motors, power off the aircraft first, then power off the Ground Control Station.
  2. Thermal Inspection: Carefully touch each motor bell and battery casing to check for abnormal overheating (indicating bearing wear or excessive current draw).
  3. Debris Removal: Brush away dust, grass, sand, or moisture from cooling vents, gimbal motors, and obstacle sensors.
  4. Data Offload: Back up flight imagery and flight logs before formatting cards.

4. Scheduled Maintenance & Component Lifecycle

Follow manufacturer interval guidelines or the baseline schedule below (whichever comes first) and record all maintenance in the aircraft's permanent Maintenance Logbook.

Component Inspection Interval Mandatory Replacement / Action
Propellers Before every flight Replace every 50–100 flight hours, after any hard landing/strike, or immediately upon visible wear
LiPo / LiHV Flight Batteries Before & after every flight Retire at 200 charge cycles, if capacity drops below 80%, or immediately if swelling/damage occurs
Brushless Motors Every 25 flight hours Clean dust with compressed air; replace if bearings grind, overheat, or develop shaft play
Gimbal Dampers & Ribbon Cables Every 25 flight hours Replace rubber dampers every 100 flight hours or if torn/stretched
Airframe & Folding Hinges Every 50 flight hours Tighten structural fasteners; replace worn arm hinges or cracked shell sections
IMU & Vision Sensors Every 100 flight hours Run full factory sensor calibration via manufacturer assistant software

5. Battery Storage & Handling Rules (LiPo / LiHV)

Lithium-Polymer batteries pose a severe fire risk if mishandled. All crew members must strictly observe these rules: